OPC and .NET with COM Interoperability

By | 8 Jul 2001 | Article
How to access OPC (OLE for Process Control) from .NET with advanced COM interop

Sample Image

Abstract

In industrial automation, OPC (OLE for Process Control, see www.opcfoundation.org) is the primary COM component interface used to connect devices from different manufactures. The OPC standard is defined at 'two different layers' of COM/DCOM. First, as a collection of COM custom interfaces, and secondly as COM-automation compliant components/wrappers. For some reasons and applications, it is preferable to use the custom interface directly.

We will show you in this article how to access OPC servers with custom interfaces and how to write an OPC client in .NET.

The problem

The new Microsoft .NET Framework will provide some interoperability layers and tools to reuse a large part of the existing COM/ActiveX/OCX components, but with some strong limitations. While automation compliant COM objects will be nicely imported (as referenced COM objects inside Visual Studio .NET, or with the TLBIMP tool), pure custom COM interfaces will not work.

To understand the issues with COM custom interfaces and the .NET framework, we must first analyze, why automation components can be used immediately. Visual Studio .NET relies on the information found in a type-library for every imported COM component (e.g. the library generated by MIDL-compiler, named *.TLB). The problem is now, type libraries can only contain automation compliant information. So if we compile a custom-interface IDL file, the generated TLB misses very important type descriptions, especially the method call parameter size (e.g. of arrays). At the time of .NET Beta2, there's unfortunately no tool (like 'IDLIMP') to import custom interface IDL files.

Example: Since the MIDL compiler does not propagate size_is information to the type library, the marshaler doesn't know an array length and translates int[] to ref int.

One first solution would be to edit the assembly produced by TLBIMP (using ILDASM), and replace ref int with int[], and then compile IL back again with ILASM.

But if we look at some very custom IDL files, we also find methods with parameters like foo( int **arraybyref ) where arrays are passed by reference (caller allocates the memory)! Hand editing IL code won't work here, there's no marshaling signature for this. Currently, we must use one of two different workarounds:

  • Write a custom marshaler (e.g. in Managed C++)
  • Or the way we used, write a marshaling helper class (in C#)

The solution, first step

We have to rewrite our custom IDL file in a managed language code, here C#. Note this can be a very time consuming work! every method of all interfaces have to be coded in C#, and the critical (custom) parameters must be declared completely different. We found there's often no way around the use of the special IntPtr type.

Let's look at a sample method (from an OPC custom interface IDL):

HRESULT AddItems(
  [in]                        DWORD            dwCount,
  [in,  size_is( dwCount)]    OPCITEMDEF     * pItemArray,
  [out, size_is(,dwCount)]    OPCITEMRESULT ** ppAddResults,
  [out, size_is(,dwCount)]    HRESULT       ** ppErrors    );

Redefined in C#, looks now like this:

int AddItems(
  [In]       int       dwCount,
  [In]       IntPtr    pItemArray,
  [Out]  out IntPtr    ppAddResults,
  [Out]  out IntPtr    ppErrors );

As you can see, we loose many type information by declaring parameters as IntPtr!

Another point is the default exception mapping of .NET: as custom interface methods return HRESULT values, failed calls will be converted by the .NET marshaller to exceptions of type COMException. Further, some COM methods will also return other success codes besides S_OK, mainly S_FALSE. With the default mapping, this hint return value will be lost.

To bypass exception mapping, declare the interface with special signature attributes. See at the code below for the head of the final interface declaration:

  [ComVisible(true), ComImport,
  Guid("39c13a54-011e-11d0-9675-0020afd8adb3"),
  InterfaceType( ComInterfaceType.InterfaceIsIUnknown )]
internal interface IOPCItemMgt
  {
    [PreserveSig]
  int AddItems(
    [In]       int       dwCount,
    [In]       IntPtr    pItemArray,
    [Out]  out IntPtr    ppAddResults,
    [Out]  out IntPtr    ppErrors );
  ...

The solution, second step

To use the interfaces we declared as above, it is recommended to write some wrapper classes. But more important, this wrapper now has to do all the custom marshaling, e.g. for all IntPtr parameters. So the wrapper must reconstruct the information we lost. Managed marshaling code makes use of the framework services provided in the System.Runtime.InteropServices namespace, especially the Marshal class. We found the following methods as useful for this:

AllocCoTaskMem() FreeCoTaskMem() SizeOf() manage COM native memory (as pointed to by IntPtr)
StructureToPtr() PtrToStructure() DestroyStructure() marshaling of simple structures
ReadInt32() WriteInt32() Copy() read/write to native memory (also -Byte/Int16/Int64)
PtrToStringUni() StringToCoTaskMemUni() string marshaling
GetObjectForNativeVariant() GetNativeVariantForObject() conversions between VARIANT and Object
ThrowExceptionForHR() map HRESULT to exception and throw
ReleaseComObject() finally, release COM object

To get the idea, see a simplified excerpt for the sample method AddItems() we declared above - here we allocate native memory and marshal an array of structures into it:

...
IntPtr ptrdef = Marshal.AllocCoTaskMem( count * sizedefinition );
int rundef = (int) ptrdef;
for( int i = 0; i < count; i++ )
  {
  Marshal.StructureToPtr( definitions[i], (IntPtr) rundef, false );
  rundef += sizedefinition;
  }

int hresult = itemsinterface.AddItems( count, ptrdef, ... );
  ...
int rundef = (int) ptrdef;
for( int i = 0; i < count; i++ )
  {
  Marshal.DestroyStructure( (IntPtr) rundef, typedefinition );
  rundef += sizedefinition;
  }
Marshal.FreeCoTaskMem( ptrdef );
...

Download

In the download package, you will find the complete interface declarations and a sample client application showing how to use them.

Please note:

  • First read the included whitepaper
  • To run this OPC client, you must have any OPC-DA 2.0 servers installed!

Useful links

OPC, the OPC logo, and OPC Foundation are trademarks of the OPC Foundation. .NET, the .NET logo, and Microsoft .NET are trademarks of the Microsoft Corporation.

Disclaimer

The information in this article & source code are published in accordance with the Beta2 bits of the .NET Framework SDK).

License

This article has no explicit license attached to it but may contain usage terms in the article text or the download files themselves. If in doubt please contact the author via the discussion board below.

A list of licenses authors might use can be found here

About the Author

VISCOM .NET Team



United States United States

Member



Sign Up to vote   Poor Excellent
Add a reason or comment to your vote: x
Votes of 3 or less require a comment

Comments and Discussions

 
You must Sign In to use this message board. (secure sign-in)
 
Search this forum  
 FAQ
    Noise  Layout  Per page   
  Refresh
QuestionOPC and safearray exception PinmemberMember 77063565:48 9 May '12  
GeneralMy vote of 5 Pinmembermanoj kumar choubey18:16 28 Feb '12  
QuestionOPC Pinmemberanand.phaniraj3:46 10 Feb '12  
QuestionOPC client error while adding items in groups PinmemberLearning WIX19:26 5 Feb '12  
AnswerRe: OPC client error while adding items in groups PinmemberDevilGeek21:00 20 Feb '12  
QuestionIsuue regarding connection with OPC server PinmemberLijomon T George2:48 11 Jan '12  
QuestionCannot connect to server PinmemberMember 77167889:09 7 Dec '11  
QuestionHow to solve the error 0x80004002 ? PinmemberMember 4808385:07 19 Oct '11  
QuestionDescription item [modified] Pinmembercavasconcelos7:13 11 May '11  
GeneralConnecting to remote server PinmemberDeathwing2314:42 24 Mar '11  
GeneralCan't register OPCdotNETLib.dll in Windows 7 Home Premium PinmemberOkoro1:28 24 Aug '10  
GeneralRemote OPC Server ---- > ReadData ???? (datavalue, timestamp,quality ) PinmemberFIRAT 201022:09 12 Aug '10  
GeneralRe: Remote OPC Server ---- > ReadData ???? (datavalue, timestamp,quality ) PinmemberJan Hussaarts3:06 9 Nov '10  
GeneralRe: Remote OPC Server ---- > ReadData ???? (datavalue, timestamp,quality ) Pinmemberkavvis_21:30 21 Feb '11  
GeneralMultiple Read Pinmemberersin382:46 4 Dec '08  
GeneralFrozen Data detection Pinmemberharpreetsinghchd18:30 17 Nov '08  
GeneralRe: Frozen Data detection PinmemberJanislav Dimitrov3:21 14 Apr '10  
General[Message Deleted] PinmemberThiago Tozim8:05 31 Jul '08  
GeneralRe: Just use Mega OPC Data Logger Pinmemberdimas19717:49 18 Oct '08  
GeneralProblem in connecting to Citect OPC Server Pinmembermahmoodsalamah232:12 7 May '08  
GeneralRe: Problem in connecting to Citect OPC Server Pinmembermahmoodsalamah234:39 11 May '08  
GeneralRe: Problem in connecting to Citect OPC Server Pinmemberyesidh8:01 8 Jul '08  
GeneralRe: Problem in connecting to Citect OPC Server Pinmembermahmoodsalamah238:23 16 Dec '08  
GeneralHelp please Pinmembermegdouli4:01 2 May '08  
GeneralRe: Help please Pinmemberrockeylau20:44 11 Mar '10  

General General    News News    Suggestion Suggestion    Question Question    Bug Bug    Answer Answer    Joke Joke    Rant Rant    Admin Admin   

Use Ctrl+Left/Right to switch messages, Ctrl+Up/Down to switch threads, Ctrl+Shift+Left/Right to switch pages.

Permalink | Advertise | Privacy | Mobile
Web02 | 2.5.120517.1 | Last Updated 9 Jul 2001
Article Copyright 2001 by VISCOM .NET Team
Everything else Copyright © CodeProject, 1999-2012
Terms of Use
Layout: fixed | fluid