Introduction

In this article I will explain how to communicate with PLC (Programmable Logic Controller). I started my PLC communication program using .NET from 2007.

For a basic understanding of what PLC is, use Google because basically I am not a PLC Engineer or Electrical Engineer, but I will explain to you how to connect PLC using .NET programs, how to read data from PLC, and how to write data to PLC. My sample programs are all based on MELSEC PLC using TCP/IP communication.

There are different kinds of PLC available like MELSEC ,SIMENS, and etc. For each PLC communication there are different types of protocols available. In this demo program I have used TCP IP communication for MELSEC PLC.

Here I have mentioned .NET programs instead of a language in .NET. In my article you will find four Zip files:

  1. SPLCSharpConnect.zip contains the PLC component DLL source code. I started PLC communication programming in 2007. At that time I was coding using VB.NET. I created my own Winsock component using VB.NET. Even now for PLC communication I am using the same Winsock component MelsecPLC.dll in my projects. In that component I have created simple functions as Connect, Disconnect, Read, Write, and a DataArrival event. In the sample project I have attached I have used the same DLL.

Before we start PLC communication programming, I'd like to explain the read and write processes in PLC communication.

Read Data from PLC

PLC Read Command: To read data from PLC we need to send the command to PLC. Basically the command we send will be like this: "500000FF03FF000018000A04010000D*0095000001";

String   cmd = "";
cmd = cmd + "5000" ;  // sub HEAD (NOT)
cmd = cmd + "00"  ;  //   network number (NOT)
cmd = cmd + "FF"  ;  //PLC NUMBER
cmd = cmd + "03FF" ; // DEMAND OBJECT MUDULE I/O NUMBER
cmd = cmd + "00" ;  //  DEMAND OBJECT MUDULE DEVICE NUMBER
cmd = cmd + "001C"  ;//  Length of demand data
cmd = cmd + "000A"; //  CPU inspector data
cmd = cmd + "0401"; //  Read command (to read the data from PLC we should "0401"
cmd = cmd + "0000" ;//  Sub command
cmd = cmd +"D*"  ;//   device code
cmd = cmd + "009500"; //adBase 
cmd = cmd + "0001";
//Device No ,It’s a Address every PLC device will have an address
//we need to send the appropriate address to read the data.

Write Data to PLC

PLC Write Command: To write data to PLC we need to send the command to PLC. Basically the command we send will be like this: "500000FF03FF00001C000A14010000D*0095010002".

String   cmd = ""; 

cmd = cmd + "5000";// sub HEAD (NOT)
cmd = cmd + "00";//   network number (NOT)
cmd = cmd + "FF";//PLC NUMBER
cmd = cmd + "03FF";// DEMAND OBJECT MUDULE I/O NUMBER
cmd = cmd + "00";//  DEMAND OBJECT MUDULE DEVICE NUMBER
cmd = cmd + "001C";//  Length of demand data
cmd = cmd + "000A";//  CPU inspector data
cmd = cmd + "1401";//  Write command
cmd = cmd + "0000";//  Sub command
cmd = cmd + "D*";//   device code
cmd = cmd + "009501"; //adBase 
cmd = cmd + "0002";  //BASE ADDRESS

You can see the difference, to read we use "0401" and "009500" but for write we use "1401" and "009501". The detailed code will be listed below.

Using the Code

I have attached C# sample programs for PLC communication in this article but for explanation here, Here I have used my component MelsecPLC.dll in the test project. First add MelsecPLC.dll to your project.

1. Delcare MelsecPLC.dll in the form

//
using MelsecPLC;

2. Variable declarations

//
public MelsecPLC.Winsock winsock1; // Declare the MelsecPLC Winsock Component
string Jig01; // To store the PLC read data.

3. Connect (PLC connection)

For connection we need the PLC IP address. Here my PLC IP address is “10.126.224.221”. Enter the local port and remote port. Here I have used “1027” for the local port and “8000” for the remote port. In form load, we call the PLC Connect function and we create a MelsecPLC DataArrival event. The DataArrival event will be triggered when PLC sends data to the PC (our computer).

The detailed connect functions and DataArrival declaration in the form load are listed below.

//
private void Form1_Load(object sender, EventArgs e)
{
    winsock1Connect();
    winsock1.DataArrival += 
      new MelsecPLC.Winsock.DataArrivalEventHandler(winsock1_DataArrival);
    timer1.Enabled = true;
    timer1.Start();
}

private void winsock1Connect()
{
    try
    {
        if (winsock1.GetState.ToString() != "Connected")
        {
            winsock1.LocalPort = 1027;
            winsock1.RemoteIP ="10.126.224.221";
            int a = 8000;
            winsock1.RemotePort = 8000;
            winsock1.Connect();
        }
    }
    catch (Exception ex)
    {
    }
}

4. DataArrival Event

In the DataArrival event we get the actual data send by PLC after the Read signal is sent to PLC. This event will be triggered whenever PLC sends data to the PC. To get data from PLC we use the winsock1.GetData() method.

//
private void winsock1_DataArrival(MelsecPLC.Winsock sender, int BytesTotal)
{
    String s = String.Empty;
    winsock1.GetData(ref s);
    Jig01 = s;
}

5. Read data from PLC

To read data from PLC we need to send the signal to PLC for data read. I have explained the read functions in my article introduction. To send read signal to PLC, we use the winsock1.Send() method.

//
private void btnRead_Click(object sender, EventArgs e)
{
    if (winsock1.GetState.ToString() != "Connected")
    {
        winsock1Connect();
    }
    //String cmd = "500000FF03FF000018000A04010000D*0095000001";
    String cmd = "";
    String OutAddress = "0001";
    cmd = "";
    cmd = cmd + "5000" ;// sub HEAD (NOT)
    cmd = cmd + "00"  ;//   network number (NOT)
    cmd = cmd + "FF"  ;//PLC NUMBER
    cmd = cmd + "03FF"   ;// DEMAND OBJECT MUDULE I/O NUMBER
    cmd = cmd + "00"  ;//  DEMAND OBJECT MUDULE DEVICE NUMBER
    cmd = cmd + "001C"  ;//  Length of demand data
    cmd = cmd + "000A";//  CPU inspector data
    cmd = cmd + "0401";//  Read command
    cmd = cmd + "0000" ;//  Sub command
    cmd = cmd +"D*"  ;//   device code
    cmd = cmd + "009500"; //adBase 
    cmd = cmd + OutAddress;  //BASE ADDRESS           
    winsock1.Send(cmd);         
}

6. Write data to PLC

To write data to PLC we need to send the signal to PLC for data write. I have explained the write functions in my article introduction. To send a write signal to PLC here we use the winsock1.Send() method.

//
private void btnWrite_Click(object sender, EventArgs e)
{
    if (winsock1.GetState.ToString() != "Connected")
    {
        winsock1Connect();
    }      
    String cmd = "";
    String OutAddress = txtWrite.Text.Trim();
    cmd = "";
    cmd = cmd + "5000";// sub HEAD (NOT)
    cmd = cmd + "00";//   network number (NOT)
    cmd = cmd + "FF";//PLC NUMBER
    cmd = cmd + "03FF";// DEMAND OBJECT MUDULE I/O NUMBER
    cmd = cmd + "00";//  DEMAND OBJECT MUDULE DEVICE NUMBER
    cmd = cmd + "001C";//  Length of demand data
    cmd = cmd + "000A";//  CPU inspector data
    cmd = cmd + "1401";//  Write command
    cmd = cmd + "0000";//  Sub command
    cmd = cmd + "D*";//   device code
    cmd = cmd + "009501"; //adBase 
    cmd = cmd + OutAddress;  //BASE ADDRESS
    winsock1.Send(cmd);
}

Points of Interest

I love to work and play with HMI (Human Interface Program). I have worked with several HMI programs using C#, like PLC, Sensor Programming, and NutRunner tool communication program. I want readers to benefit from this program.

History

  • Initial release: 2013/07/05.

License

This article, along with any associated source code and files, is licensed under The Code Project Open License (CPOL)

Share

About the Author

syed shanu
Team Leader
India India
Microsoft MVP | Code Project MVP | CSharp Corner MVP | Author | Blogger and always happy to Share what he knows to others. MyBlog

My Interview on Microsoft TechNet Wiki Ninja Link

You may also be interested in...

Pro
Pro

Comments and Discussions

 
QuestionArduino connect Pin
Member 135995304-Jul-18 2:02
memberMember 135995304-Jul-18 2:02 
Questionmitsubishi PLC using randon road Pin
Member 1194342319-Oct-17 7:53
memberMember 1194342319-Oct-17 7:53 
QuestionHow to read the data from Panasonic PLC FP-X series using Visual Studio in C#? Pin
Member 133531638-Aug-17 23:24
memberMember 133531638-Aug-17 23:24 
QuestionPLC Communication using VB 6.0 Pin
Member 1331424317-Jul-17 9:57
memberMember 1331424317-Jul-17 9:57 
Questionwinsock1_DataArrival does not get triggered. Pin
Member 1313742026-Apr-17 2:51
memberMember 1313742026-Apr-17 2:51 
QuestionFX3GE Pin
jvbeek4-Apr-17 5:10
memberjvbeek4-Apr-17 5:10 
Questionis there need of instoling mecsec.dll file to run this code Pin
Member 127978836-Mar-17 22:05
memberMember 127978836-Mar-17 22:05 
QuestionConfiguring Pin
Member 1297101228-Feb-17 8:44
memberMember 1297101228-Feb-17 8:44 
QuestionMelsec PLC Communication Pin
Member 1299674917-Feb-17 17:25
memberMember 1299674917-Feb-17 17:25 
QuestionArray of Registers Pin
MustafaAquil8-Sep-16 18:22
professionalMustafaAquil8-Sep-16 18:22 
QuestionOut address mean what sir can u plz Pin
Member 1258200823-Jun-16 20:09
memberMember 1258200823-Jun-16 20:09 
SuggestionRe: Out address mean what sir can u plz Pin
smmoon6-Jul-16 21:09
membersmmoon6-Jul-16 21:09 
GeneralRe: Out address mean what sir can u plz Pin
Member 127181165-Sep-16 3:21
memberMember 127181165-Sep-16 3:21 
GeneralRe: Out address mean what sir can u plz Pin
smmoon1-Dec-16 16:35
membersmmoon1-Dec-16 16:35 
QuestionCan u Plz Help to read and write from plc Pin
Member 1258200823-Jun-16 20:00
memberMember 1258200823-Jun-16 20:00 
AnswerRe: Can u Plz Help to read and write from plc Pin
Garth J Lancaster23-Jun-16 20:08
professionalGarth J Lancaster23-Jun-16 20:08 
GeneralRe: Can u Plz Help to read and write from plc Pin
Member 1258200823-Jun-16 20:17
memberMember 1258200823-Jun-16 20:17 
Questionquestion about mitsubishi plc Pin
Frq Sdq22-Jun-16 23:24
memberFrq Sdq22-Jun-16 23:24 
GeneralMy vote of 1 Pin
smmoon16-Jun-16 17:29
membersmmoon16-Jun-16 17:29 
GeneralRe: My vote of 1 Pin
syed shanu16-Jun-16 17:35
mvpsyed shanu16-Jun-16 17:35 
GeneralRe: My vote of 1 Pin
smmoon16-Jun-16 17:36
membersmmoon16-Jun-16 17:36 
GeneralRe: My vote of 1 Pin
syed shanu16-Jun-16 17:40
mvpsyed shanu16-Jun-16 17:40 
GeneralRe: My vote of 1 Pin
smmoon16-Jun-16 17:42
membersmmoon16-Jun-16 17:42 
GeneralRe: My vote of 1 Pin
syed shanu16-Jun-16 17:44
mvpsyed shanu16-Jun-16 17:44 
GeneralRe: My vote of 1 Pin
smmoon16-Jun-16 18:02
membersmmoon16-Jun-16 18:02 

General General    News News    Suggestion Suggestion    Question Question    Bug Bug    Answer Answer    Joke Joke    Praise Praise    Rant Rant    Admin Admin   

Use Ctrl+Left/Right to switch messages, Ctrl+Up/Down to switch threads, Ctrl+Shift+Left/Right to switch pages.

Permalink | Advertise | Privacy | Cookies | Terms of Use | Mobile
Web05-2016 | 2.8.180810.1 | Last Updated 21 Jan 2015
Article Copyright 2015 by syed shanu
Everything else Copyright © CodeProject, 1999-2018
Layout: fixed | fluid