Great info. Thanks for sharing links and models. I will be buying one soon. I was wondering if those smaller units would help with brownouts, because that is what I'm really wanting it for.
|
|
|
|
|
I have always had a UPS and never had problems with sparking. The problems I have had are batteries dying after a few years resulting in battery replacement when economical or unit replacement when not, failure to kick in quickly enough form some early APC units and figuring out where to place them and the tangle of power cords.
|
|
|
|
|
Thanks for the info. That's what everyone is reporting...no sparks...just battery replacement issues which is normal expectation.
|
|
|
|
|
We get many thunderstorms where I live. Power is glitchy even w/o the storms.
I used an APC 1400 SmartUPS for many years.
One thing to make sure you a unit with the capacity to handle the load you have on it.
I replaced the tower machine I used at the time with an HP Z800 with an 1100W power supply. Never gave the size of the APC unit a thought until the Z800 killed the UPS.
Discovered that HP recommends a 2200VA unit for the Z800. I got the APC 2200 SmartUPS unit.
It gets delivered by a tractor trailer on a skid. Unit weighs 110 Lbs. Took two people to lug it up to my ROG. And they typically take a special power cord. Mine required an L5 outlet.
Normally, you'd want that load on a 220V circuit, since the ROG is the 4th bedroom I didn't think it would be too wise to have a 220V circuit in what might at some point (after I am out of the house) revert back and become a child's bedroom.
Even if you aren't using a machine as large as the HP, best to make sure that you match the capacity of the unit to the equipment you are plugging into it. And keep in mind the UPS will likely outlast you computer, so it is probably wise to get a unit larger than your immediate need.
|
|
|
|
|
That's a large unit.
Thanks for the info. I will be getting one I can carry myself.
|
|
|
|
|
I have lots of the APC UPSs at my house.
Each time the battery wears out (small battery supplying huge currents) I buy a new UPS right away. Costco has good prices for them.
After I replace the battery in the retired one, it moves to protect some other thing in the house.
There's now also a UPS on the TV+settop box, the router+modem, the expensive computerized sewing machine, the NAS, my wife's computer upstairs, and (most recently) a lamp in the family room.
|
|
|
|
|
|
APC 2200XL for years and never an issue other than changing batteries after 5 years.
|
|
|
|
|
Thanks for sharing. that's what others are reporting too...no problems, just battery change.
|
|
|
|
|
I have used APC UPSes for many years, on both sides of the Atlantic. Other than needing batteries replaced, I have only had two fail on me - one after almost 11 years of continuous use (it stopped charging the battery), and one after a couple of weeks' use (persistent error indication). I called APC's support up about the latter and, after I described the symptoms, they shipped me a new one out overnight express, with a prepaid shipping label to return the defective one in the same packaging. I did once buy a 'store-brand' UPS, and it died within 18 months. I have no experience with CyberPower. I have also certainly never seen a UPS fail in the exciting way described by the reviewers you quote.
|
|
|
|
|
Good to know. Thanks for sharing the info.
|
|
|
|
|
Yes, used an APC for years. Just replaced the battery and - the best bit - they have a recycling system for old batteries, so there is a carton out waiting for the courier.
|
|
|
|
|
Good UPSs don't fail with sparks that could start a fire. I've used a number of them over the years (APC, Belkin), and the only thing that seems to fail are the batteries, which wear out and need replacing from time to time.
As for surge protectors, there are two kinds, the MOS ones, where the MOS part takes the hit, burning it out a little more each time, and series mode ones, which use a large inductor and don't wear out (they're also hard to find, heavy as snot, and expensive).
BTW, a lot of shills copy their reviews onto many sites, so just because you see it on multiple sites, doesn't mean it isn't from a shill, nor even that it's true. It's not called the 'net of a million lies' for nothing
|
|
|
|
|
Great info. Thanks for your input. Also, i'm reading that wikipedia entry too.
|
|
|
|
|
Hey, my local library has the ebook copy of the Vernor Vinge book available and I just checked it out. Very cool to find good new reading material. Thanks again.
|
|
|
|
|
Vinge's works are some of my favorites, with that series in particular being some of my favorites among his work. That particular series is really interesting for the aliens.. which are really alien.. but not.
We're almost to the hexapodia moment.
|
|
|
|
|
FYI - I read through the (long) prologue of Vinge's Fire Upon the Deep and I also completed chapter 1.
The prologue was tough because you can't tell what or who is the viewpoint character.
I'm still guessing, but I'm guessing it is an AI from the way it was worded. That really was some tough reading, but interesting too.
Now with chapter 1 we get the human viewpoint and that makes it a lot better. Chapter 1 was really good.
I think now that I got past the tough prologue this is going to be an interesting story.
If nothing else it is quite mysterious.
Thanks again for the recommendation.
|
|
|
|
|
I have APC units all over my house, we get a lot of thunderstorms in Louisiana and have never had a problem or moments worry. I had a couple of units' batteries requiring replacement, but a local battery shop handles all of my needs.
Try not to overload them by using up every sing slot, and pay attention to the VA rating relative to the things you are plugging in.
Sparkless for years now.
|
|
|
|
|
Great info. Thanks for your input. I really appreciate the lounge here providing all this great feedback. I feel a lot better about buying one now. Although I think I am going to buy from a local store instead of internet so I hopefully escape any knock-offs.
|
|
|
|
|
Advice I was given about UPS (by someone who worked for a UPS manufacturer --- I think APC, but I'm not sure).
Never plug a surge suppresser into a UPS. UPSes have to convert DC to AC. The easiest way to do that is to create a stair-step wave instead of a proper sine wave. Surge suppressors see that as thousands of tiny surges per second that need to be suppressed. This could lead to overheating/sparks/fires. (Note, I was told this about 20 years ago, so UPSes and/or surge suppressors may have found a solution to this)
Truth,
James
|
|
|
|
|
That is really fantastic information. Glad to know that. Thanks so much for taking the time to let me know.
|
|
|
|
|
I can spend a 100 hours or more working on some code, and it takes less than 2 minutes to demo it to the customer.
I suppose many things are like that. Imagine the thousands and thousands of hours put into the design, manufacturing, testing, and assembly of a rocket. What does the customer see? Ooh, that was a cool launch, and look, 5 minutes later the booster landed on a barge at sea, with big rolling waves no less!
|
|
|
|
|
Yeah, most things in life are like that. Sprinters train for years and their "work" is done in 10 seconds.
Cheers,
विक्रम
"We have already been through this, I am not going to repeat myself." - fat_boy, in a global warming thread
|
|
|
|
|
|
If you can keep your head while those about you are losing theirs, perhaps you don't understand the situation.
|
|
|
|